🔌 خطأ مصدر الليزر
Laser source error
❗Work in the diagnostic program should be entrusted to the equipment supplier's technical specialist or a private master❗
❗All errors related to the source going into error are solved by rebooting the source.
You can reboot the source 2 times, then it will go into software lock, requiring connection through diagnostic program and error removal.
Other source repair methods involve replacing its blocks:
1) Power supply for diodes often fails — for this reason, equipment must work with a voltage stabilizer;
2) Optical cable burnout or break is treated only by full fiber optic replacement (requires specialized service);
3) Chip or burnout of optical fiber quartz connector can be repaired by polishing the connector. ❗BE CAREFUL WITH CONNECTOR POLISHING SPECIALIST SELECTION❗;
4) When power fades, diode replacement is possible, but work cost may equal new source cost.
❗BEFORE REMOVING ERROR, CHECK LOG FILE WITH ERROR TYPE TO UNDERSTAND CRITICALITY❗
You can find the diagnostic program for your source type and power on manufacturer official sites by clicking the button below.
❗Work in the diagnostic program should be entrusted to the equipment supplier's technical specialist or a private master❗
❗All errors related to the source going into error are solved by rebooting the source.
You can reboot the source 2 times, then it will go into software lock, requiring connection through diagnostic program and error removal.
Other source repair methods involve replacing its blocks:
1) Power supply for diodes often fails — for this reason, equipment must work with a voltage stabilizer;
2) Optical cable burnout or break is treated only by full fiber optic replacement (requires specialized service);
3) Chip or burnout of optical fiber quartz connector can be repaired by polishing the connector. ❗BE CAREFUL WITH CONNECTOR POLISHING SPECIALIST SELECTION❗;
4) When power fades, diode replacement is possible, but work cost may equal new source cost.
❗BEFORE REMOVING ERROR, CHECK LOG FILE WITH ERROR TYPE TO UNDERSTAND CRITICALITY❗
You can find the diagnostic program for your source type and power on manufacturer official sites by clicking the button below.